潘金莲一级淫片aaaaaa播放-亚洲免费观看高清-伊人网在线视频-丝袜一区-男女拍拍拍-日本一级黄色-欧美1区2区-麻豆回家视频区一区二-嫩草视频在线播放-日批免费看-www.爱情岛-日韩精品四区-96在线视频-国产在线h-日韩在线免费播放-人人看人人澡-大胸动漫-人人搞人人插-蜜臀aⅴ国产精品久久久国产老师-成人影片在线-黄色片成人-久久艹久久-丝袜影音先锋-爆操杨幂-精品无码人妻一区二区免费蜜桃-另类激情视频-四虎一区二区三区-人妻aⅴ无码一区二区三区-一乃葵在线-日韩中文电影

產品展示
PRODUCT DISPLAY

打印當前頁

免費咨詢:021-67610176

發郵件給我們:market@hsiyen.cn

分享到:
產品展示您現在的位置: 首頁 > 產品展示 > > 美國戴安Dionex > 069580美國戴安Dionex Acclaim Carbamate LC Column 液相色譜柱

美國戴安Dionex Acclaim Carbamate LC Column 液相色譜柱

簡要描述:

戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其*達80%。與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。   
戴安公司的快速溶劑萃取儀15分鐘之內僅用15毫升溶劑既可完成對10g樣品的萃取,該技術已在環境、藥物、食品和聚合物工業等領域得到廣泛應用。

型號 069580
廠商性質 代理商
更新日期 2017-10-31

美國戴安Dionex Acclaim Carbamate LC Column 液相色譜柱

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技術參數:


Acclaim Carbamate Column Specifications
Column chemistryProprietary alkyl group
Operating pressure limit (recommended)6000 psi (4000 psi)
Operating pH range (recommended)2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended)0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats
訂購信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm)075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm)075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm)072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm)072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm)072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm)072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2)072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2)072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2)072930
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7